Science and Research
Studien zur FaceFormer Therapie
Studien zur FaceFormer Therapie
In controlled pilot study, the success of the Face Former Therapy in Patients with snoring and sleep apnea was determined. A three-month long phase of therapy of four exercises daily was necessary. One exercise unit included 20 repeats of a basic exercise and 20 repeats of minimally one circuit exercise. After three weeks if nose breathing improved through the exercise, the Face Former device was also used during night. The goal was to make a habit of nose breathing.
2002/03/25 – 2003/01/30
Six evaluation appointments
Entry examination, afterwards four appointments after the first three weeks and one after three months.
Thirty-eight test persons began the evaluation
Only 30 test persons were evaluated, who took part in six control appointments and reported regularly with protocol to the exercise course (N=30).
Selected patients: Diagnosed with sleep apnea symptoms
RDI > 18, Independent of sex, 8 w, 22 m
The body mass index was determined at the initial examination.
N = 30
Max = 39
Min = 19
Patient were chose who had files about their polysomnographical evaluation results from sleep laboratories or from outpatient evaluations. The data were chose as base values for the evaluation. All diagnoses were not older than six months. The patients had guaranteed that they were not to undergo other therapy treatments during the Face Former Therapy. Some patients, whom were handled with NCPAP and BIPAP, no longer used or stopped using the devices for reasons of poor acceptance. None of the test persons had undergone an operation for snoring.
During the control appointments, the patients recorded their own assumptions to the changes in sleep, daily tiredness, vigilance and to the effect on the general state of being in a scale from one to ten (1 = worst, 10 = best).
During every appointment measurement of lip strength were taken with the ISST Myo Bar Meter and recorded as real-time diagnostics. Thereby, the assumption was made that an improved lip strength increased the probability that the mouth closed during the sleep phase and through the nightly closure of the mouth, nose breathing could become habit.
After 12 weeks, every patient took part in an outpatient polysomnographical evaluation. The evaluation was repeated again after three months (six months after therapy start). The results were used as the final evaluation data.
Before therapy, all patients had noticeable snoring episodes.
No snoring (Level 1)
before: 0 test persons
after: 16 test persons
Classification in 4 levels
N = 30
Wert 1 = none
Wert 2 = few
Wert 3 = some
Wert 4 = many
RDI before and after therapy
N = 30
RDI before therapy = 18-25
RDI after therapy = 1-14
Percentual RDI progress within 12 weeks
N = 30
Average improvement = 70,81%
Lowest improvement = 50%
Highest improvement = 88,89%
Breathing interruptions in seconds
N = 30
before therapy = 8-48
after therapy = 1-14
Average oxygen supply
before and after therapy
N = 30
before therapy = 71-99
after therapy = 89-99
Lip force before and after therapy
N = 30
before therapy = 18-35 mBar
after therapy = 45-68 mBar
At the beginning of the study, no participant reached the minimum standard value of 36 mBar when measuring lip strength. At the end of the study, all of them were significantly above this value. No participant was below 45 mBar.
Progress of lip force within 12 weeks
N = 30
average value = 102,93%
minimal increase = 41,18%
maximal increase = 172,22%
N = 30
rating scale 1-10
worst value = 1
best value = 10
ISST Unna
Wasserstr. 25
D-59423 Unna
Email: buero@isst-unna.de
Tel.: +49-2303/86888
You can purchase your FaceFormer online in the Dr. Berndsen Shop, from our sales partners or from numerous doctors and therapists or locally in your pharmacy.
Ask for the central pharmaceutical number PZN 18092273 (FaceFormer ONE blue).
Further product variants and useful accessories are available.
Saving tip especially for doctors and therapists: 20%++ discount on orders of 5 FaceFormers or more!
The effective solution for snoring, sleep apnea, CMD, jaw problems and many other indications. Simple, causal, effective.
Der FaceFormer ONE Der FaceFormer, ein Medizinprodukt der Klasse 1, ist aus medizinischem Elastosil gefertigt und garantiert schadstofffrei. Die Therapie zielt darauf ab, fehlerhafte Funktionsabläufe zu korrigieren, die verschiedene Symptome beeinflussen können. Seit zwei Jahrzehnten stellt die FaceFormer-Therapie eine…
Die FaceFormer® Therapie: Der FaceFormer, ein Medizinprodukt der Klasse 1, ist aus medizinischem Elastosil gefertigt und garantiert schadstofffrei. Die Therapie zielt darauf ab, fehlerhafte Funktionsabläufe zu korrigieren, die verschiedene Symptome beeinflussen können. Seit zwei Jahrzehnten stellt die FaceFormer-Therap…
Der neue FaceFormer® ZERO Auf vielfachen Anwenderwunsch hat die FaceFormer Familie Zuwachs bekommen. Zusätzlich zum bekannten FaceFormer ONE in blau oder kristallklar ist ab sofort der FaceFormer ZERO erhältlich. Was ist anders? Der FaceFormer ZERO weist eine geringere Materialhärte auf, als die bisherigen Modelle. Grö…
FaceFormer® ZERO & ONE Therapie-Set für Erwachsene Überblick: Dieses Therapie-Set umfasst die Modelle FaceFormer ZERO und FaceFormer ONE. Beide sind als medizinische Geräte der Klasse 1 aus medizinischem Elastosil® hergestellt und sind BPA-frei sowie frei von flüchtigen Stoffen. Sie sind speziell darauf ausgelegt, die …
Wasserstr.25
59423 Unna
Germany
+49 (0) 23 03-89 99 1
+49 (0) 23 03 – 89 88 6
Mo. to Fr. from 8:00 to 16:00
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
OK, agree with allAgree to essentialsShow settingsThe satisfaction of visitors to our website is important to us. In order to better address you, we use cookies. Thereby we achieve that the website works technically reliable and secure.
You can change or revoke your consent at any time.
In the privacy policy you can learn more about cookies and privacy setting.
View privacy policy
Essential cookies enable basic functionality and are necessary for the proper functioning of the website.
This data may be linked to user information of users logged in on youtube.com and google.com.
YouTube video embedding
Used to unlock YouTube content.
Google Analytics
Cookie from Google for website analytics.
Generates statistical data about how the visitor uses the website